Name : NetR9 Summary : Trimble NetR9 Full Firmware Package (NetR9_v44x.timg), versions 4.41/4.42/4.43 Versions : 4.41/4.42/4.43 ========================================================= Trimble NetR9 Firmware Versions 4.41/4.42/4.43 Addendum ========================================================= This is an addendum to the Trimble NetR9 firmware Release Notes for versions 4.41, 4.42, and 4.43. The above referenced released versions contain enhancements to power control routines. As a result, the default power-on value will reset to 15V after a firmware upgrade. These releases are not recommended to be installed remotely for any systems operating on less than 15V power. They can be safely installed locally at the receiver, but will require a manual power-on of the receiver after the firmware upgrade is complete if 12V DC power is used at the site. Note that this only affects receivers which are: - using a power source less than 15V, and - running a firmware version less than v4.4x and being upgraded to one of the above noted versions All other units using an AC power adapter or power sources greater than 15V will accept the firmware remotely with no user interaction.